Pure Water Generation System :

WTS offers the Pure Water Generation System & Distribution system for Pharma applications to meet USP grade water quality.

USP Grade Water Quality of Purified Water Generation System:

  • Conductivity: < 1.3 µS/cm @ 25 ºC
  • Total Bacterial Count (TBC) : < 100 CFU / ml
  • Total Organic Carbon (TOC): < 500 ppb

Standard Features: (For Generation System)

  • 4” or 8” TFC Spiral wound membranes
  • SS 304 / 316 housing for the membranes
  • SS 304 Fabricated Skid
  • SS 304 / 316 Multi Stage Vertical Pump with Accessories
  • 5 micron Cartridge Pre Filter with SS Housing

Eletrodeionization System for Polishing (Plate & Frame Type)

  • The Electro De Ionization (EDI) offered by us are used to produce pure water, which is free from any type of infections or contamination.
  • In order to meet stringent water quality standards our system uses electrolysis process which generates consistent water quality having the least conductivity level. Furthermore, the specialty of this system is that the dissolved salts can be removed with low energy cost and without the need for chemical regeneration and hence it is environment friendly with negligible operating cost.
  • SS 304 / SS 316 Piping for higher version like electro polished.
  • Low pressure switch
  • High pressure switch
  • Liquid filled pressure gauges, panel mount for pump suction, membrane feed, and final concentrate
  • Permeate conductivity monitor
  • Permeate & concentrate flow meters
  • Completely pre wired control panel and an electrical switch gear panel / PLC based control Panel

Standard Features: (For Distribution System)

  • Distribution Tank with Jacketed / Heating Coil / Electrical heater
  • SS 316 L contact Part & SS 304 Non Contact Part
  • Tank with Leg mounting arrangement
  • 0.2 Micron Hydrophobic type Vent Filter assembly
  • Special Feature – Rupture Disk (Optional)
  • Distribution Transfer Pump – Sanitary Construction
  • Ultra violate Sterilizer for the Disinfection
  • SS 316 L piping & Fittings with Electro polished
  • Zero Dead Leg Valve at the End of the User points ( L < 3 d)
  • Insulation to be provided for the Hot / Cold water Distribution
  • SS 304 Fabricated Skid
  • Online Conductivity Monitoring
  • Return line velocity / Flow Monitoring
  • Return line Temperature Monitoring
  • Online TOC Monitoring